Powerful and Quiet: Pulsar 9500 Watt Dual Fuel Inverter Generator | Unboxing
Table of Contents
- Introduction
- Specifications of the Pulsar 9500 Dual Fuel Inverter Generator
- Unboxing and Initial Setup
- Understanding the Oil Filter System
- Filling the Generator with Oil
- Checking the Battery and Air Filter
- Exploring the Plug Options and Circuit Breakers
- Testing the Generator on Propane
- Measuring the Noise Levels
- Comparison with Other 9,000-Watt Generators
Introduction
In this article, we will be taking an in-depth look at the Pulsar 9500 Dual Fuel Inverter Generator. This powerful generator is capable of producing 9,500 watts of power and is designed for versatile use, whether it be for home backup, worksites, RVs, tailgating, or running sensitive equipment. We will explore its specifications, unbox and set it up, discuss its unique oil filter system, fill it with oil, check the battery and air filter, examine the plug options and circuit breakers, test it on propane, measure the noise levels, and finally compare it with other generators in its category. So, let's dive in and discover all there is to know about the Pulsar 9500 Dual Fuel Inverter Generator.
Specifications of the Pulsar 9500 Dual Fuel Inverter Generator
Before we delve into the details, let's first take a look at the specifications of the Pulsar 9500 Dual Fuel Inverter Generator. This generator boasts a peak starting power of 9,500 watts and a rated running power of 7,600 watts on gasoline. If you choose to run it on propane, the peak starting power is slightly lower at 8,550 watts and the rated running power is 7,200 watts. It operates at a quiet 62 dB, making it suitable for various settings. The Pulsar 9500 is equipped with a sine wave remote start and offers multiple plug options, including a full-size 50-amp plug, a 30-amp 240V plug, and four 120V plugs. It also features parallel capability and has a USB port for conveniently charging devices. With these specifications in mind, let's proceed to the unboxing and initial setup of the generator.
Unboxing and Initial Setup
Upon receiving your Pulsar 9500 Dual Fuel Inverter Generator, you will notice that it comes in a well-packaged box. The generator is securely protected with plywood, Styrofoam, and thick cardboard on all sides. To remove the generator from the box, flip it over to the side and open the bottom. This will allow you to easily lift the generator out. It is recommended to have someone assist you in this process to make it easier. Once the generator is out of the box, you will find various accessories and components, including the remote control, propane lines, oil, adapter for making cables, funnel, and spark plug tool. Take a moment to familiarize yourself with these items and the overall appearance of the Pulsar 9500 Dual Fuel Inverter Generator.
Understanding the Oil Filter System
One notable feature of the Pulsar 9500 Dual Fuel Inverter Generator is its unique oil filter system. Unlike other generators that rely solely on magnets to attract and remove metal shavings from the oil, the Pulsar 9500 comes with an oil screen that can be easily cleaned. To access the oil filter, you will need to remove the side panel of the generator by unscrewing the three bottom screws. Once the panel is removed, you will find the oil screen, which may have accumulated metal shavings and debris. It is important to clean this screen periodically to ensure the longevity and optimal performance of the generator. Simply rinse the screen with water, let it dry thoroughly, and place it back in the generator. This innovative oil filter system sets the Pulsar 9500 apart from its competitors and contributes to its overall effectiveness.
Filling the Generator with Oil
Before starting the Pulsar 9500 Dual Fuel Inverter Generator, it is essential to fill it with the appropriate amount of oil. The generator holds approximately 1.17 quarts or 37.2 ounces (equivalent to 1.1 liters) of oil. To fill the generator, locate the oil fill port and remove the cap. Place a towel or rag beneath the port to catch any spilled oil and prevent a mess. It is important to use the correct type of oil, as specified by the manufacturer. In this case, the recommended oil is 10W-30. Fill the generator with oil until it reaches the top of the oil level indicator. Be careful not to overfill, as it can lead to issues with the generator's performance. Once the appropriate amount of oil is added, securely place the dipstick back on and ensure it is not cross-threaded.
Checking the Battery and Air Filter
To ensure smooth operation, it is crucial to check the battery and air filter of the Pulsar 9500 Dual Fuel Inverter Generator. The battery is located on one side of the generator and may be disconnected for safety during transit. Before starting the generator, make sure the battery is securely connected by attaching the appropriate cables. Additionally, inspect the air filter for any dirt or debris that may hinder airflow. The air filter can be accessed by unscrewing a small screw located nearby. This easy access allows for quick inspection and cleaning, if necessary. It is important to check the spark plug as well, as it may become disconnected during shipping. Verify that it is securely in place to avoid any unnecessary return procedures.
Exploring the Plug Options and Circuit Breakers
The Pulsar 9500 Dual Fuel Inverter Generator offers a variety of plug options and features circuit breakers for added safety. On the front panel of the generator, you will find full-size 50-amp, 30-amp 240V, and four 120V plugs. These outlets cater to different power requirements and allow you to connect various devices and appliances simultaneously. Additionally, there are two reset buttons for the 20-amp plugs. The generator's circuit breakers are also conveniently located on the front panel, ensuring easy access in case of overload or tripping. The Pulsar 9500 Dual Fuel Inverter Generator is designed to be parallel capable, allowing you to connect multiple generators for increased power output. This feature makes it a versatile and reliable option for various applications.
Testing the Generator on Propane
One of the standout features of the Pulsar 9500 Dual Fuel Inverter Generator is its ability to run on both gasoline and propane. To test the generator on propane, you will need to connect the provided inlet hose to the propane tank's LPG connection. Ensure that the fuel regulator is properly connected and open the pressure regulator. Set the generator to the propane mode and leave the eco mode on for fuel efficiency. To start the generator, you can either use the remote control or the push-to-start button on the front panel. Once the generator is running, you can monitor its performance and noise levels. Speaking of noise levels, let's discuss how to measure them accurately.
Measuring the Noise Levels
The Pulsar 9500 Dual Fuel Inverter Generator is advertised as a quiet generator, operating at around 62 dB. To accurately measure the noise levels, it is recommended to use a decibel (DB) meter. Position the DB meter approximately 10 feet away from the generator and note the reading. Move further away, maintaining a predetermined distance, and record the results at different distances. This will give you an idea of the noise levels emitted by the generator at various distances. It is important to note that the noise levels may increase when the generator is under a heavy load. This is a common characteristic of many generators. By understanding the noise levels, you can assess the generator's compatibility with your desired application.
Comparison with Other 9,000-Watt Generators
To provide a comprehensive overview, it is essential to compare the Pulsar 9500 Dual Fuel Inverter Generator with other generators in its category. A comparison will serve as a basis for evaluating its performance, features, and value for money. In the next article, we will put the Pulsar 9500 next to generators such as the Predator, Gen Max, and Duramax, which are all similar in terms of wattage output. By comparing these generators side by side, we will analyze their similarities and differences, helping you make an informed decision when choosing a generator for your specific needs.
Highlights
- The Pulsar 9500 Dual Fuel Inverter Generator offers a peak starting power of 9,500 watts and a rated running power of 7,600 watts on gasoline, making it suitable for various applications.
- The unique oil filter system of the Pulsar 9500 allows for easy cleaning and maintenance, ensuring optimum performance and longevity.
- The generator can be easily set up and operated, with features such as a remote control, multiple plug options, circuit breakers, and parallel capability.
- It is designed to run on both gasoline and propane, providing flexibility and convenience for different fuel preferences.
- Noise levels can be measured and monitored using a decibel meter, allowing users to assess the generator's suitability for specific environments.
- A comparison with other 9,000-watt generators will provide insights into the performance and value of the Pulsar 9500 Dual Fuel Inverter Generator.
FAQ
Q: Can the Pulsar 9500 Dual Fuel Inverter Generator run on propane and gasoline simultaneously?
A: No, the generator can only run on either propane or gasoline at a time. It provides versatile fuel options depending on the user's preference.
Q: Is the Pulsar 9500 Dual Fuel Inverter Generator suitable for sensitive electronic equipment?
A: Yes, the generator produces a clean sine wave output, which is safe for running sensitive electronics and equipment.
Q: Can the Pulsar 9500 Dual Fuel Inverter Generator be used for camping or tailgating?
A: Yes, the generator is portable and suitable for outdoor activities such as camping and tailgating. However, it is important to follow local regulations and guidelines regarding generator usage in public spaces.
Q: Does the Pulsar 9500 Dual Fuel Inverter Generator come with a warranty?
A: Yes, the generator typically comes with a manufacturer's warranty. It is recommended to check the warranty details and any specific terms and conditions provided by the manufacturer.
Q: What maintenance is required for the Pulsar 9500 Dual Fuel Inverter Generator?
A: Regular maintenance tasks include checking and replacing the oil, cleaning the air filter, inspecting the spark plug, and ensuring proper fuel storage and handling. It is recommended to refer to the generator's user manual for detailed maintenance instructions.