Troubleshooting Predator 2000 Inverter Generator Won't Start
Table of Contents:
- Introduction
- Background on the Predator 2000 generators
- The issue with oil and fuel in the carburetors
- Finding a solution online
- Replacing the carburetors
- Step-by-step guide to removing the carburetor
- Replacing the carburetor with a new one
- Testing the newly installed carburetor
- Using the Predator 2000 generators with a log splitter
- Conclusion
Introduction
In this article, we will be discussing the Predator 2000 generators and how to fix an issue that arises with them. These generators were purchased two years ago and have not been used since. However, when the owner tried to start them, they wouldn't start due to oil and fuel build-up in the carburetors. After a search for a solution, a website called Power Equipment was found, where new carburetors were purchased. In the following paragraphs, we will provide a step-by-step guide on how to replace the carburetors and get the generators up and running again, as well as discuss their use with a log splitter.
Background on the Predator 2000 generators
The Predator 2000 generators were purchased about two years ago, with the intention of using them for a camper during boondocking trips. However, they have never been used, and as a result, the oil and fuel in the carburetors became a problem. The owner decided to find a solution to fix the carburetor issue and make the generators functional.
The issue with oil and fuel in the carburetors
When the Predator 2000 generators were purchased, the seller stated that the oil had been drained and the fuel burned out. However, after two years of non-use, the carburetors still contained oil and fuel, which had gummed up and prevented the generators from starting. This is a common issue that requires the carburetors to be replaced.
Finding a solution online
After discovering the problem with the carburetors, the owner of the Predator 2000 generators searched online for a solution. The website Power Equipment was found, which offered new carburetors for purchase. The decision was made to order the new carburetors from this website to fix the issue and get the generators running again.
Replacing the carburetors
Replacing the carburetors in the Predator 2000 generators is a necessary step to resolve the start-up issue. By replacing the old carburetors with new ones, the oil and fuel build-up is eliminated, allowing the generators to function properly. The following paragraphs will provide a detailed guide on how to remove the old carburetors and replace them with the new ones.
Step-by-step guide to removing the carburetor
To begin the process of replacing the carburetors, start by removing the three bolts on the side of the generator that holds the carburetor in place. This will allow access to the carburetor for replacement. Next, remove the bolts on the exhaust side and take off the piece covering the carburetor. With this side removed, the fuel tank can be raised to provide enough space to remove the carburetor.
Replacing the carburetor with a new one
Once the old carburetor has been successfully removed, it can be replaced with the new one obtained from Power Equipment. Carefully align the new carburetor in the correct position and make sure to connect the fuel line and throttle cable securely. After the new carburetor is in place, reassemble all the parts that were removed, including covers and screws, to ensure everything is secure.
Testing the newly installed carburetor
After replacing the old carburetor with a new one, it is important to test the generator to ensure that it is now functioning properly. With the carburetor replaced, turn the generator on and observe if it starts smoothly. Allow the generator to run for a few minutes to ensure that the fuel is flowing correctly. If everything is running smoothly, the generator is now fixed and ready to be used.
Using the Predator 2000 generators with a log splitter
The Predator 2000 generators can also be used in conjunction with a log splitter. This is particularly useful in situations where there is no electricity close to where the logs are piled. By connecting the log splitter to the generators, it is possible to split logs without the need for a nearby power source. The generators provide the necessary power to operate the log splitter effectively.
Conclusion
In conclusion, the Predator 2000 generators can experience issues with oil and fuel build-up in the carburetors if not used for an extended period. However, with the help of online resources, such as Power Equipment, it is possible to find a solution and replace the carburetors. By following the step-by-step guide provided in this article, owners of the Predator 2000 generators can effectively resolve the start-up issue and have fully functioning generators. Additionally, these generators can be used in conjunction with a log splitter to facilitate wood splitting tasks in areas without access to electricity.