Unveiling the Hidden Defect of Onan RV Generator
Table of Contents
- Introduction
- The Hidden Issue with Onan 4000 Micro Quiet Cummins Generators
- The Simple Repair for a Big Issue
- Understanding the Start/Stop Problem
- The Faulty Plastic Dipstick
- Proper Oil Levels and Readings
- Running the Generator to Get Accurate Readings
- Solving the Start/Stop Issue
- The Costly Repairs and Aggravations
- Conclusion
The Hidden Issue with Onan 4000 Micro Quiet Cummins Generators
Introduction
In this article, we will discuss a hidden issue that plagues Onan 4000 Micro Quiet Cummins generators, often found in RVs. While many people spend thousands of dollars on repairs and replacement parts, there is a simple solution that solves the problem. We will dive into the details of this issue, explain the repairs, and provide you with a step-by-step guide to fix the start/stop problem once and for all.
The Simple Repair for a Big Issue
If you've ever experienced your Onan 4000 Micro Quiet Cummins generator suddenly dying while in use, only to start up again a short while later, you're not alone. Many RV owners have dealt with this frustrating and perplexing problem. Countless hours and dollars have been wasted on replacing parts, such as fuel pumps and motherboards, without a proper resolution. However, the solution to this issue is incredibly simple, and even a 5-year-old could handle it.
Understanding the Start/Stop Problem
The start/stop problem on Onan generators is often attributed to excessive high oil levels. While the manual mentions this as a potential cause, the parameters for what constitutes "excessive" oil are misleading. Most people expect to fill their oil up to the full mark, just as they would in their cars or other vehicles. However, with these specific generators, filling the oil up to the full mark leads to the start/stop issue.
The Faulty Plastic Dipstick
The root cause of the start/stop problem lies in a seemingly innocent component - the plastic dipstick. The dipstick, as designed by Onan, has a full mark that extends too far up, causing the oil level to be deemed excessive even when it is within the acceptable range. This faulty dipstick has gone unnoticed and unchanged for years, leading to countless headaches and wasted money for RV owners.
Proper Oil Levels and Readings
To solve the start/stop problem, it is crucial to adjust the oil level correctly. Instead of filling the oil up to the full mark as indicated by the faulty dipstick, it is recommended to keep it no more than 1/4 of the way above the add line. This adjustment ensures that the oil level is within the acceptable range and prevents the generator from shutting down unexpectedly.
Running the Generator to Get Accurate Readings
To get an accurate reading of the oil level, it is important to run the generator for a specific duration. If your RV has been stationary for a prolonged period, the oil may have settled, leading to an inaccurate reading. It is advisable to run the generator for 30 to 45 minutes on reasonably level ground before checking the oil level. After shutting off the generator, wait for at least 8 hours before checking the oil. This waiting period allows the oil to settle properly, providing a true reading.
Solving the Start/Stop Issue
By adjusting the oil level to be no more than 1/4 above the add line and following the proper oil checking procedure, you can effectively solve the start/stop issue plaguing Onan 4000 Micro Quiet Cummins generators. This simple fix has been tested and proven to work for the majority of affected generators. By implementing this solution, you can save yourself hundreds or even thousands of dollars in unnecessary repairs and replacements.
The Costly Repairs and Aggravations
Unfortunately, many RV owners have already spent a significant amount of money on repairs and replacements due to the start/stop problem. Some individuals have wasted thousands of dollars, thinking that the issue lies in faulty parts or complex technical faults. Little did they know that the solution was as simple as adjusting the oil level. This faulty plastic dipstick has caused an immense amount of aggravation and confusion, leaving RV owners frustrated and disillusioned.
Conclusion
In conclusion, the hidden issue with Onan 4000 Micro Quiet Cummins generators can be easily resolved with a simple adjustment. By addressing the faulty plastic dipstick and ensuring the oil level stays no more than 1/4 above the add line, you can prevent your generator from shutting down unexpectedly. This straightforward solution will save you time, money, and unnecessary hassle. Don't let the start/stop problem ruin your RV experience; follow these steps, and enjoy uninterrupted power on your adventures.